Electromagnetic reversing valve
Wiring box type
DIN connector type
S- |
DSG |
-01 |
-2 |
B |
2 |
A |
-D24 |
-C |
-N★4 |
-70 |
-L |
Model |
Series |
Specifications |
Valve location number |
Valve Core Spring Arrangement |
Valve element type |
Mark only with valves in the middle and side positions |
Coil type |
Manual operation form |
Electrical wiring form |
Design number |
Reverse type of electromagnet |
No mark:standard type |
DSG:
Electromagnetic reversing valve |
01 |
3 |
C:
Spring back |
2、3、4、9、10、11、12、40、60 |
—— |
Alternating current :
A100、A120、A200、A240
Direct current:
D12、D24、D48
Alternating current:
Ac (dc rectifier)
R100、R200
|
No mark:
hand operated putter
C:
With button lock type
|
No mark:wiring box type
N:DIN with power indicator plug type (optional)
N1★2 :DIN with power indicator plug type (optional)
|
70 |
—— |
2 |
D:
No spring positioning |
2 |
—— |
B:
Spring reset |
2、3、8 |
A★1:Use the neutral position and electromagnet a power-on position
B★1:Use the neutral position and electromagnet b power-on position
|
L:
Mark only when the electromagnet is reversed
|
★1、For details on valves using the intermediate position and the side position, refer to "Using the intermediate position and the side position".
★2、N1: DIN with power-on indicator plug type does not have straight-through rectification type (coil type R*)
★3、A valve for phosphate ester is available. However, a special seal (fluororubber) is required for the phosphate ester solution. Please add [F-] in front of the model when ordering.
★4、Special wiring methods include M12-4 pin plug type, valve body center DIN plug type, M12-4 pin DIN connector type and DEUTSCH plug type. (Please refer to the "Special Wiring Method" at the end of the page)